In this paper a thermodynamic analysis of a gas turbine class G with temperature of exhaust gas to the expander of 1500°C, compression ratio 23, which uses air film cooling in an open-loop was conducted. The analyzed gas turbine has been integrated with three steam cycle models: single pressure (1P), dual pressure with interstage steam reheat, triple pressure with interstage steam reheat (3PR). Models of combined cycle power plants (CCPP) were built in the GateCycle™. In the following section of the paper steam cycles were integrated with CO2 capture installation through the use of steam bleed for regeneration of sorbent in absorber -striper system. The captured carbon dioxide has been compressed to the pressure of 15 MPa to prepare for transport. Comparison of net electrical power and efficiency of the combined cycle power plants with and without CO2 capture and compression installation.

Przetłumaczony tytuł wkładuInfluence of CCS on efficiency of combined cycle power plants
Język oryginałupolski
Strony (od–do)81-86
Liczba stron6
CzasopismoRynek Energii
Tom106
Numer wydania3
Status publikacjiOpublikowano - 2013

Cele SDG ONZ

Ten wynik przyczynia się do realizacji następujących celów zrównoważonego rozwoju

  1. Cel 13 - Działanie na rzecz klimatu
    Cel 13 Działanie na rzecz klimatu

Słowa kluczowe

  • CO capture
  • Combined cycle power plants
  • Gas turbine
  • Heat recovery steam generator
  • Steam cycle

Obszary tematyczne ASJC Scopus

  • Matematyka ogólna
  • Energia ogólna

Fingerprint

Zanurz się w tematy badawcze publikacji „Wplyw instalacji CCS na sprawność ukladów gazowo -parowych”. Razem tworzą niepowtarzalny odcisk palca.

Cytowanie