TY - GEN
T1 - Use of local convective and radiant cooling at warm environment
T2 - 10th International Conference on Healthy Buildings 2012
AU - Melikov, Arsen K.
AU - Duszyk, Marcin
AU - Krejciríková, Barbora
AU - Sakoi, Tomonori
AU - Kaczmarczyk, Jan
PY - 2012
Y1 - 2012
N2 - The effect of four local cooling devices (convective, radiant and combined) on thermal comfort and perceived air quality reported by 24 subjects at 28 °C and 50% RH was studied. The devices studied were: (1) desk cooling fan, (2) personalized ventilation providing clean air, (3) two radiant panels and (4) two radiant panels with one panel equipped with small fans. A reference condition without cooling was tested as well. The response of the subjects to the exposed conditions was collected by computerized questionnaires. The cooling devices significantly (p<0,05) improved subjects' thermal comfort compared to without cooling. The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and PAQ increased when the local cooling methods were used. The best results were achieved with personalized ventilation and cooling fan. The improvement in PAQ when the radiant panel was used alone was minimal.
AB - The effect of four local cooling devices (convective, radiant and combined) on thermal comfort and perceived air quality reported by 24 subjects at 28 °C and 50% RH was studied. The devices studied were: (1) desk cooling fan, (2) personalized ventilation providing clean air, (3) two radiant panels and (4) two radiant panels with one panel equipped with small fans. A reference condition without cooling was tested as well. The response of the subjects to the exposed conditions was collected by computerized questionnaires. The cooling devices significantly (p<0,05) improved subjects' thermal comfort compared to without cooling. The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and PAQ increased when the local cooling methods were used. The best results were achieved with personalized ventilation and cooling fan. The improvement in PAQ when the radiant panel was used alone was minimal.
KW - Air movement control
KW - Human response
KW - Personalised ventilation
KW - Warm environment
UR - https://www.scopus.com/pages/publications/84883314918
M3 - Conference contribution
AN - SCOPUS:84883314918
SN - 9781627480758
T3 - 10th International Conference on Healthy Buildings 2012
SP - 1044
EP - 1049
BT - 10th International Conference on Healthy Buildings 2012
Y2 - 8 July 2012 through 12 July 2012
ER -