Uplift-induced failure mechanism of an integrated steel-masonry headframe building caused by chemically active shaft backfill

  • GEOdev

Wyniki badań: Wkład do czasopisma › Artykuł › recenzja

Abstrakt

This paper presents an analysis of the causes of failure in a rare historic headframe tower, constructed as an integrated steel–masonry structural system. The structure experienced severe wall cracking after shaft closure. The study aimed to identify the governing damage mechanism and its root cause. The investigation combined geotechnical field and laboratory testing, hydrogeochemical and mineralogical analyses, geodetic measurements, and finite element modelling. The geotechnical assessment showed that the strength and stiffness of the native subsoil beneath the building foundations were sufficient and that the observed damage could not be explained by conventional settlement mechanisms. Chemical and X-ray diffraction analyses of the backfill indicated the presence of gypsum, calcite, and thaumasite, suggesting sulphate- and carbonate-related reactions associated with volumetric expansion. Swelling tests confirmed the expansive behaviour of the anthropogenic backfill material. Geodetic measurements recorded a significant shaft-slab uplift of 71 cm, and the calibrated numerical model reproduced this displacement, supporting the mechanical plausibility of the proposed failure mechanism. The results indicate that the failure mechanism was governed by swelling of the shaft backfill, which induced uplift of the shaft head and incompatible deformations in the integrated steel–masonry structure. The study demonstrates that chemically active shaft backfill may generate substantial uplift and incompatible deformations in buildings structurally integrated with shaft infrastructure, and provides a mechanism-oriented diagnostic framework for distinguishing uplift-induced failure from conventional settlement-related building damage.

Język oryginałuangielski
Numer artykułu117266
CzasopismoJournal of Building Engineering
Tom131
Identyfikatory DOI
Status publikacjiOpublikowano - 1 wrz 2026

Obszary tematyczne ASJC Scopus

  • Architektura
  • Inżynieria lądowa i strukturalna
  • Budownictwo
  • Bezpieczeństwo, ryzyko, niezawodność i jakość
  • Mechanika materiałowa

Fingerprint

Zanurz się w tematy badawcze publikacji „Uplift-induced failure mechanism of an integrated steel-masonry headframe building caused by chemically active shaft backfill”. Razem tworzą niepowtarzalny odcisk palca.

Cytowanie