Abstrakt
During the identification of lithium-ion cell equivalent circuit parameters based on HPPC (Hybrid Pulse Power Characterization) measurement results, time constants of the recorded voltage transients are identified. A significant practical problem is that the identified time constants, in the case of LFP (LiFePO₄) cells, are longer than the test pulse duration. Therefore, a solution to this problem was proposed by including in the identification process the transient recorded after the test pulse ceases, during the significantly longer cell relaxation period. This resulted in an identification method based on two components, enabling more precise identification of cell time constants.
| Przetłumaczony tytuł wkładu | Dwuskładnikowa aproksymacja impulsów HPPC w badaniach identyfikacyjnych cel litowo-jonowych LiFePO4 |
|---|---|
| Język oryginału | angielski |
| Czasopismo | Przeglad Elektrotechniczny |
| Tom | 102 |
| Numer wydania | 6 |
| Identyfikatory DOI | |
| Status publikacji | Opublikowano - 2026 |
Obszary tematyczne ASJC Scopus
- Inżynieria elektryczna i elektroniczna
Fingerprint
Zanurz się w tematy badawcze publikacji „Dwuskładnikowa aproksymacja impulsów HPPC w badaniach identyfikacyjnych cel litowo-jonowych LiFePO4”. Razem tworzą niepowtarzalny odcisk palca.Cytowanie