Abstrakt
This article describes a thermodynamic analysis of an oxy type power plant. The analyzed power plant consists of: 1) steam turbine for supercritical steam parameters of 600 oC/29 MPa with a capacity of 600 MW; 2) circulating fluidized bed boiler, in which brown coal with high moisture content (42.5%) is burned in the atmosphere enriched in oxygen; 3) air separation unit (ASU); 4) CO 2 capture installation, where flue gases obtained in the combustion process are compressed to the pressure of 150 MPa. The circulated fluidized bed (CFB) boiler is integrated with a fuel dryer and a cryogenic air separation unit. Waste nitrogen from ASU is heated in the boiler, and then is used as a coal drying medium. In this study, the thermal efficiency of the boiler, steam cycle thermal efficiency and power demand were determined. These quantities made possible to determine the net efficiency of the test power plant.
| Język oryginału | angielski |
|---|---|
| Strony (od–do) | 123-136 |
| Liczba stron | 14 |
| Czasopismo | Archives of Thermodynamics |
| Tom | 34 |
| Numer wydania | 3 |
| Identyfikatory DOI | |
| Status publikacji | Opublikowano - 2013 |
Cele SDG ONZ
Ten wynik przyczynia się do realizacji następujących celów zrównoważonego rozwoju
-
Cel 13 Działanie na rzecz klimatu
Obszary tematyczne ASJC Scopus
- Ogólna fizyka i astronomia
Fingerprint
Zanurz się w tematy badawcze publikacji „Supercritical power plant 600 MW with cryogenic oxygen plant and CCS installation”. Razem tworzą niepowtarzalny odcisk palca.Cytowanie