Abstrakt
This paper presents results of detailed reliability analysis of water distribution subsystem operation of Krakow city. Basis of the research was wide base of information of occurred failures during exploitation (1996-2006). These analysis included evaluation of basic factors such as: failure and renovation intensities, mean recovery time and mean time to failure, availability factor and probability of failure-free operation at any time. Moreover, it was performed wide analysis of failure capability of pipes as a function of its diameter and material. The paper consists also of research results of occurred piping failures reasons and consequences.
| Język oryginału | angielski |
|---|---|
| Strony (od–do) | 307-326 |
| Liczba stron | 20 |
| Czasopismo | Journal of Konbin |
| Tom | 7 |
| Numer wydania | 4 |
| Identyfikatory DOI | |
| Status publikacji | Opublikowano - 2008 |
Obszary tematyczne ASJC Scopus
- Bezpieczeństwo, ryzyko, niezawodność i jakość
Fingerprint
Zanurz się w tematy badawcze publikacji „Reliability Analysis of Water Distribution Subsystem”. Razem tworzą niepowtarzalny odcisk palca.Cytuj to
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver