TY - GEN
T1 - Placement of microphones for an active noise-reducing casing
AU - Mazur, Krzysztof
AU - Wrona, Stanislaw
AU - Pawelczyk, Marek
N1 - Publisher Copyright:
© 25th International Congress on Sound and Vibration 2018, ICSV 2018: Hiroshima Calling. All rights reserved.
PY - 2018
Y1 - 2018
N2 - Active Noise Control systems have been in scientific interest for a long time. Such systems allow for high reduction of low-frequency noise, especially for predictable noises such as tones or multitones generated by rotational machines. The obtained reduction level may be much higher compared to passive methods, which for low-frequencies require unacceptable thick and heavy barriers. Classical Active Noise Control systems, which use sound interference in air, except in some limited cases, can create only local zones of quiet, where the destructive interference occurs. In most cases this is unacceptable. Such problem can be solved by using actively controlled barriers, which can form a full active noise-reducing casing. Then, by appropriate control of wall vibrations, a significant global noise reduction can be achieved. However, both global noise level and noise emission cannot be measured. Some estimations or limited measurements need to be used. One of possible solutions is to measure the noise emission by using multiple microphones around the casing. In this paper different configurations of microphone placement are investigated. Microphones are used by a feed-forward FXLMS-based control system for adaptation of control filter weights. The control systems are tested on an off-the-shelf washing machine casing with electrodynamic actuators installed on four walls. The performance of the resulting control systems is experimentally verified and obtained results are reported.
AB - Active Noise Control systems have been in scientific interest for a long time. Such systems allow for high reduction of low-frequency noise, especially for predictable noises such as tones or multitones generated by rotational machines. The obtained reduction level may be much higher compared to passive methods, which for low-frequencies require unacceptable thick and heavy barriers. Classical Active Noise Control systems, which use sound interference in air, except in some limited cases, can create only local zones of quiet, where the destructive interference occurs. In most cases this is unacceptable. Such problem can be solved by using actively controlled barriers, which can form a full active noise-reducing casing. Then, by appropriate control of wall vibrations, a significant global noise reduction can be achieved. However, both global noise level and noise emission cannot be measured. Some estimations or limited measurements need to be used. One of possible solutions is to measure the noise emission by using multiple microphones around the casing. In this paper different configurations of microphone placement are investigated. Microphones are used by a feed-forward FXLMS-based control system for adaptation of control filter weights. The control systems are tested on an off-the-shelf washing machine casing with electrodynamic actuators installed on four walls. The performance of the resulting control systems is experimentally verified and obtained results are reported.
KW - Active casing
KW - Active noise control
KW - Structural control
KW - Washing
UR - https://www.scopus.com/pages/publications/85058683127
M3 - Conference contribution
AN - SCOPUS:85058683127
T3 - 25th International Congress on Sound and Vibration 2018, ICSV 2018: Hiroshima Calling
SP - 944
EP - 951
BT - 25th International Congress on Sound and Vibration 2018, ICSV 2018
PB - International Institute of Acoustics and Vibration, IIAV
T2 - 25th International Congress on Sound and Vibration 2018: Hiroshima Calling, ICSV 2018
Y2 - 8 July 2018 through 12 July 2018
ER -