Przeskocz do nawigacji głównej Przeskocz do wyszukiwania Przeskocz do głównej treści

In vitro evaluation of electrochemically bioactivated Ti6Al4V 3D porous scaffolds

  • Alexandr Myakinin
  • , Amanzhol Turlybekuly
  • , Alexander Pogrebnjak
  • , Adam Mirek
  • , Mikhael Bechelany
  • , Iryna Liubchak
  • , Oleksandr Oleshko
  • , Yevheniia Husak
  • , Viktoriia Korniienko
  • , Katarzyna Leśniak-Ziółkowska
  • , Dmitry Dogadkin
  • , Rafał Banasiuk
  • , Roman Moskalenko
  • , Maksym Pogorielov
  • , Wojciech Simka
  • D. Serikbayev East Kazakhstan Technical University
  • Nazarbayev University
  • Sumy State University
  • Farabi University
  • UMR CNRS n. 5635
  • Polish Academy of Sciences
  • Silesian University of Technology
  • NanoWave
  • Institute of Biotechnology and Molecular Medicine
  • Nano Prime

Wyniki badań: Wkład do czasopismaArtykułrecenzja

60 Cytowania z bazy Scopus

Abstrakt

Triply periodic minimal surfaces (TPMS) are known for their advanced mechanical properties and are wrinkle-free with a smooth local topology. These surfaces provide suitable conditions for cell attachment and proliferation. In this study, the in vitro osteoinductive and antibacterial properties of scaffolds with different minimal pore diameters and architectures were investigated. For the first time, scaffolds with TPMS architecture were treated electrochemically by plasma electrolytic oxidation (PEO) with and without silver nanoparticles (AgNPs) to enhance the surface bioactivity. It was found that the scaffold architecture had a greater impact on the osteoblast cell activity than the pore size. Through control of the architecture type, the collagen production by osteoblast cells increased by 18.9% and by 43.0% in the case of additional surface PEO bioactivation. The manufactured scaffolds demonstrated an extremely low quasi-elastic modulus (comparable with trabecular and cortical bone), which was 5–10 times lower than that of bulk titanium (6.4–11.4 GPa vs 100–105 GPa). The AgNPs provided antibacterial properties against both gram-positive and gram-negative bacteria and had no significant impact on the osteoblast cell growth. Complex experimental results show the in vitro effectiveness of the PEO-modified TPMS architecture, which could positively impact the clinical applications of porous bioactive implants.

Język oryginałuangielski
Numer artykułu111870
CzasopismoMaterials Science and Engineering C
Tom121
Identyfikatory DOI
Status publikacjiOpublikowano - lut 2021

Obszary tematyczne ASJC Scopus

  • Bioinżynieria
  • Medycyna ogólna
  • Biomateriały

Fingerprint

Zanurz się w tematy badawcze publikacji „In vitro evaluation of electrochemically bioactivated Ti6Al4V 3D porous scaffolds”. Razem tworzą niepowtarzalny odcisk palca.

Cytuj to