Abstrakt
In this investigation, ignition processes of the methane and the propane using a high-temperature oxidizer (T oxi > T ai) with a varying oxygen concentration z O2 - the HTAC (High Temperature Air Combustion) conditions, applying a constant-volume bomb (CVB) was investigated. The influence of the initial temperature of the oxidizer T oxi was analyzed and discussed. It is shown that in order to achieve an effective reaction of ignition the oxidizer temperature needn't be maximized. Detailed evolution of ignition delay time with equivalence ratio τ ig was presented. It can be concluded that increment of oxygen concentration z O2 in oxidizer results in decrease of τ ig. Trials with propane are characterizing lower values of ignition delay time τ ig in comparison with methane.
| Język oryginału | angielski |
|---|---|
| Strony (od–do) | 145-149 |
| Liczba stron | 5 |
| Czasopismo | High Temperature Materials and Processes |
| Tom | 30 |
| Numer wydania | 1-2 |
| Identyfikatory DOI | |
| Status publikacji | Opublikowano - kwi 2011 |
Obszary tematyczne ASJC Scopus
- Materiałoznawstwo ogólne
- Fizyka materii skondensowanej
- Mechanika materiałowa
- Chemia fizyczna i teoretyczna
Fingerprint
Zanurz się w tematy badawcze publikacji „Evolution of hydrocarbons ignition delay time over HTAC (High Temperature Air Combustion) conditions”. Razem tworzą niepowtarzalny odcisk palca.Cytowanie
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver