Abstrakt

This paper describes the determination of value of frequency-independent component of ac-dc voltage transfer difference of two calculable thermal ac voltage standards developed and maintained at the Silesian University of Technology Gliwice, Poland. According to our research, the value of this parameter determined with ac-dc transfer measurements is 0.0 μV/V with combined standard uncertainty (k = 1) equal to 0.3 μV/V. The obtained results were validated with fast-reversed direct current method and will be used to supplement the uncertainty budgets of these standards. The presented method does not require expensive quantum ac voltage standards.

Język oryginałuangielski
Numer artykułu8665956
Strony (od–do)1515-1521
Liczba stron7
CzasopismoIEEE Transactions on Instrumentation and Measurement
Tom68
Numer wydania5
Identyfikatory DOI
Status publikacjiOpublikowano - maj 2019

Obszary tematyczne ASJC Scopus

  • Instrumentacja
  • Inżynieria elektryczna i elektroniczna

Fingerprint

Zanurz się w tematy badawcze publikacji „Determination of Frequency-Independent Component of AC-DC Transfer Difference of SUT Calculable AC Voltage Standards”. Razem tworzą niepowtarzalny odcisk palca.