Abstrakt
In the paper, there are presented the results of parameter estimation of the mathematical model of a synchronous generator operating in a single-machine power system. Noisy dynamic waveforms caused by introducing a disturbance in the form of a step change in the reference voltage or a pseudorandom signal to the generator voltage regulator system were the basis of estimation. It was assumed that the generator load was close to the rated one. Finite and infinite impulse response zero-phase digital filters were used for filtering the waveforms. The least squares method was used for parameter estimation, and the gradient method was applied to minimization of the mean square error.
| Przetłumaczony tytuł wkładu | Ocena dokładności estymacji parametrów modelu generatora synchronicznego przy wykorzystaniu zaszumionych przebiegów dynamicznych |
|---|---|
| Język oryginału | angielski |
| Strony (od–do) | 16-20 |
| Liczba stron | 5 |
| Czasopismo | Przeglad Elektrotechniczny |
| Tom | 91 |
| Numer wydania | 7 |
| Identyfikatory DOI | |
| Status publikacji | Opublikowano - 1 lip 2015 |
Obszary tematyczne ASJC Scopus
- Inżynieria elektryczna i elektroniczna
Fingerprint
Zanurz się w tematy badawcze publikacji „Ocena dokładności estymacji parametrów modelu generatora synchronicznego przy wykorzystaniu zaszumionych przebiegów dynamicznych”. Razem tworzą niepowtarzalny odcisk palca.Cytowanie
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver