Abstrakt
The work include a report of research works concerning applications of non-classical piezoelectric transducers in mechatronic measuring systems. Composite piezoelectric transducers called Macro Fiber Composite (MFC) are considered. Characteristics of considered transducers were made, indicating their advantages and disadvantages, as well as the results of carried out laboratory tests are presented, in which MFC transducers were used as sensors for mechatronic measurement systems. A series of laboratory tests was carried out on the created laboratory stand to determine the impact on the measured values of damage of the mechanical subsystem on which the MFC-type piezoelectric transducer was glued. Results of measurements are presented and analysed in relation to different applications of the piezoelectric MFC sensors.