Przeskocz do nawigacji głównej Przeskocz do wyszukiwania Przeskocz do głównej treści

An advanced system of thermal diagnosis with the application of neural modeling of the boilers

  • Silesian University of Technology

Wyniki badań: Rozdział w książce/raport/materiał konferencyjnyWkład w konferencjęrecenzja

3 Cytowania z bazy Scopus

Abstrakt

Generation of the information for the process of proper operational decision making represents the task for the control systems of the power unit operation. The effectiveness of the decision making is in a large extent dependent of the quality of the information accessible for decision-maker. The evaluation of existing state of operational condition is not sufficient for optimal decision making. Besides the knowledge of indices characterizing the operational conditions, the information about the influence of the operational parameters on the deviation of these indices from optimal point is also very important. Generation of such information requires the application of simulative mathematical model. There are two main groups of mathematical models. The first one represents analytical models based on physical laws. The second one are empirical models based on experimental data. Processes proceeding in energy boilers are very complicated and for this reason in this case the creation of analytical models based only on physical laws are extremely complicated and time-consuming. The development in measurements and computer techniques caused that mathematical modeling based on registered measurements data are more often applied. The paper presents the application of neural modeling method for creation of the empirical model of the boiler. The analytical-empirical models have been analyzed. In the analyzed models the dependence between input and output parameters has been approximated by means of the neural models. The possibilities of application of obtained models for exploitation control system of the boiler as well as for evaluation of the deviation of the index of specific consumption of fuel from reference level has been also demonstrated.

Język oryginałuangielski
Tytuł publikacji goszczącejECOS 2007 - Proceedings of the 20th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems
RedaktorzyOzer Arnas, Alberto Mirandola, Andrea Lazzaretto
WydawcaUniversita degli Studi di Padova
Strony303-309
Liczba stron7
ISBN (elektroniczny)9788889884089
Status publikacjiOpublikowano - 2007
Wydarzenie20th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, ECOS 2007 - Padova, Włochy
Czas trwania: 25 cze 200728 cze 2007

Seria publikacji

NazwaECOS 2007 - Proceedings of the 20th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems
Tom1

Konferencja

Konferencja20th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, ECOS 2007
Kraj/TerytoriumWłochy
MiejscowośćPadova
Okres25/06/0728/06/07

Obszary tematyczne ASJC Scopus

  • Energia ogólna
  • Ogólne nauki o środowisku

Fingerprint

Zanurz się w tematy badawcze publikacji „An advanced system of thermal diagnosis with the application of neural modeling of the boilers”. Razem tworzą niepowtarzalny odcisk palca.

Cytowanie