Abstract
Summary. The article presents the results of the experimental analysis of determining the current-voltage characteristics of colorful BIPV (Building Integrated Photovoltaics) modules. During the research, a series of photovoltaic modules was produced, including the use of various colorizing elements for the photovoltaic modules. Measurements were conducted to determine the current-voltage characteristics, as well as parameters such as open-circuit voltage (Uoc), voltage at the maximum power point (Umpp), short-circuit current (Isc), current at the maximum power point (Impp), and maximum power (Pmpp) for each module. Electroluminescence images were also taken to confirm the correctness of the photovoltaic module production. A comparative analysis of the achieved parameters was conducted.
| Translated title of the contribution | EXPERIMENTAL ANALYSIS OF CURRENT-VOLTAGE PARAMETERS OF COLOUR BIPV MODULES |
|---|---|
| Original language | Polish |
| Pages (from-to) | 28-34 |
| Number of pages | 7 |
| Journal | Rynek Energii |
| Volume | 2024 |
| Issue number | 2 |
| Publication status | Published - 2024 |