Abstract
The article presents results of laboratory tests of point--fixed laminated glass samples with local reinforcement in the form of a steel woven mesh. A total of 16, reference and reinforced samples, were tested. It was found that the reinforcement has a positive effect on the post-breakage capacity of the laminated glass. Local reinforcement in the glass increases the post-breakage strength by 51, 117 and 166% for samples with a reinforcement diameter of 75, 110 and 150 mm, respectively.
| Translated title of the contribution | Effect of local reinforcement on the post-breakage load capacity of point-fixed laminated glass |
|---|---|
| Original language | Polish |
| Pages (from-to) | 14-16 |
| Number of pages | 3 |
| Journal | Materialy Budowlane |
| Volume | 604 |
| Issue number | 12 |
| DOIs | |
| Publication status | Published - 2022 |
ASJC Scopus subject areas
- Chemical Engineering (miscellaneous)
Fingerprint
Dive into the research topics of 'Effect of local reinforcement on the post-breakage load capacity of point-fixed laminated glass'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver