Skip to main navigation Skip to search Skip to main content

Weryfikacja pomiarowa podatności wzmacniaczy operacyjnych na zaburzenia radioelektryczne

Translated title of the contribution: Experimental verification of susceptibility to EMI of operational amplifiers
  • Institute of Medical Technology and Equipment

Research output: Contribution to journalArticlepeer-review

Abstract

In the paper the experimental verification of susceptibility to EMI of chosen operational amplifiers is presented. The op-amp measurements have been performed in a test set being the differential amplifier. Applied measurement test set allows convenient examination of output DC drift in the presence of EMI by simulating a close to real-life situation in which RF signals are introduced simultaneously to both inputs of op-amp. A qualitative agreement between measurements and a simple mathematical model describing the DC offset drift of operational amplifier as a function of RF interference amplitude has been verified.

Translated title of the contributionExperimental verification of susceptibility to EMI of operational amplifiers
Original languagePolish
Pages (from-to)84-87
Number of pages4
JournalPrzeglad Elektrotechniczny
Volume94
Issue number2
DOIs
Publication statusPublished - 2018

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Experimental verification of susceptibility to EMI of operational amplifiers'. Together they form a unique fingerprint.

Cite this