Abstract
This paper presents the results of thermodynamic analyses of a system using a horizontal ground heat exchanger to cool a residential building in summer and heat it in the autumn-winter period. The main heating device is a vapour compression heat pump with the ground as the lower heat source. The aim of the analyses is to examine the impact of heat supply to the ground in the summer period, when the building is cooled, on the operation of the heating system equipped with a heat pump in the next heating season, including electricity consumption. The processes occurring in cooling and heating systems have an unsteady nature. The main results of the calculations are among others the time-dependent values of heat fluxes extracted from or transferred to the ground heat exchanger, the fluxes of heat generated by the heat pump and supplied to the heated building by an additional heat source, the parameters in characteristic points of the systems, the temperature distributions in the ground and the driving electricity consumption in the period under analysis. The paper presents results of analysis of cumulative primary energy consumption of the analyzed systems and cumulative emissions of harmful substances.
| Original language | English |
|---|---|
| Pages (from-to) | 47-72 |
| Number of pages | 26 |
| Journal | Archives of Thermodynamics |
| Volume | 37 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - 1 Mar 2016 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Ground heat exchanger
- Heat pump
- Heating system
- Numerical modelling
ASJC Scopus subject areas
- General Physics and Astronomy
Fingerprint
Dive into the research topics of 'Utilization of the horizontal ground heat exchanger in the heating and cooling system of a residential building'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver