Abstract
Mycoestrogens-contg. deionized, tap and surface waters (concn. 5 μg/L) was purified by membrane nanofiltration (active area 2.6 m2, cut-off 200-400 Da), at 20°C, transmembrane pressure 2.0 MPa and the linear velocity of the feed 3.4 m/s. The effect of water recovery degree 10-80% by vol. of the initial feed volume (20 L) on the retention of mycoestrogens was studied. The retention of zearalenone was 57-75%, while a-zearalenole 70-100%. The microcontaminant retention decreased with increasing the degree of permeate recovery.
| Translated title of the contribution | Removal of mycoestrogens from water in an industrial modules for nanofiltration |
|---|---|
| Original language | Polish |
| Pages (from-to) | 1393-1395 |
| Number of pages | 3 |
| Journal | Przemysl Chemiczny |
| Volume | 91 |
| Issue number | 7 |
| Publication status | Published - 2012 |