Abstract
Mathematical model of an induction heater with a transverse flux magnetic field is used to describe the non-stationary temperature field in a non-ferrous plate. The two three-dimensional fields are considered weakly coupled and processed using the professional software OPERA 3D to calculate the electromagnetic field, and the specially prepared software TEMP 3D to evaluate the temperature field. Examples of calculation are presented.
| Original language | English |
|---|---|
| Pages (from-to) | 361-373 |
| Number of pages | 13 |
| Journal | Acta Technica CSAV (Ceskoslovensk Akademie Ved) |
| Volume | 43 |
| Issue number | 4 |
| Publication status | Published - 1998 |