TY - GEN
T1 - Thermocouple dynamic errors correction for instantaneous temperature measurements in induction heating
AU - Konopka, Krzysztof
PY - 2013
Y1 - 2013
N2 - The most commonly used thermometer to measure high temperatures in metallurgy is the thermocouple, but because of its long response time it can be used mainly for measuring time-averaged temperatures. Research on steel wire patenting using inductive heating required instantaneous temperature values. Pyrometers or thermographic cameras could be used, however they are generally expensive, and temperature measurements are not always reliable due to differing emissivities. In described case expensive infrared thermometers could be replaced by cheap thermocouple provided that dynamic errors were corrected. Correction algorithm would not increase the total cost of the measuring system as no additional hardware is required. Correction algorithm was implemented in LabVIEW. The time constant was determined experimentally. Experiments were carried out to examine improvement in response time of thermocouple with correction algorithm.
AB - The most commonly used thermometer to measure high temperatures in metallurgy is the thermocouple, but because of its long response time it can be used mainly for measuring time-averaged temperatures. Research on steel wire patenting using inductive heating required instantaneous temperature values. Pyrometers or thermographic cameras could be used, however they are generally expensive, and temperature measurements are not always reliable due to differing emissivities. In described case expensive infrared thermometers could be replaced by cheap thermocouple provided that dynamic errors were corrected. Correction algorithm would not increase the total cost of the measuring system as no additional hardware is required. Correction algorithm was implemented in LabVIEW. The time constant was determined experimentally. Experiments were carried out to examine improvement in response time of thermocouple with correction algorithm.
KW - Correction algorithm
KW - Inductive heating
KW - Steel wire patenting
KW - Thermocouple dynamic errors
UR - https://www.scopus.com/pages/publications/84894159911
M3 - Conference contribution
AN - SCOPUS:84894159911
SN - 9781629931890
T3 - 19th IMEKO TC4 Symposium - Measurements of Electrical Quantities 2013 and 17th International Workshop on ADC and DAC Modelling and Testing
SP - 508
EP - 514
BT - 19th IMEKO TC4 Symposium - Measurements of Electrical Quantities 2013 and 17th International Workshop on ADC and DAC Modelling and Testing
T2 - 19th IMEKO TC4 Symposium - Measurements of Electrical Quantities 2013 and 17th International Workshop on ADC and DAC Modelling and Testing
Y2 - 18 July 2013 through 19 July 2013
ER -