@inproceedings{9c55f3b0ffcd4c7e837d6ae8a3be7286,
title = "The influence of the type of mortar on the compressive behaviour of walls made of Autoclaved Aerated Concrete (AAC)",
abstract = "The article describes the results of the tests on the influence of mortar on compressive strength and modulus of elasticity of the wall made of blocks of Autoclaved Aerated Concrete (AAC). The test was performed on the walls with 4 types of mortars and without mortar. There were 26 models examined in total pursuant to the guidelines of EN 1052{\textendash}1 standard. Based on the analysis of test results it was stated that the type of mortar essentially influences on the wall compression strength and level of cracking stresses. The greatest compression strength was noted for dry walls (without mortar) and walls joined with the use of polyurethane glue. The resistance of walls with thin-layer joints and with non-filled perpend joints was greater than the resistance of similar walls with filled perpend joints. The resistance of walls with normal joints and with non-filled perpend joints was smaller than the resistance of similar walls with filled vertical joints.",
author = "Drobiec and R. Jasi{\'n}ski and T. Rybarczyk",
note = "Publisher Copyright: {\textcopyright} 2016 Taylor \& Francis Group, London.; 16th International Brick and Block Masonry Conference, IBMAC 2016 ; Conference date: 26-06-2016 Through 30-06-2016",
year = "2016",
language = "English",
isbn = "9781138029996",
series = "Brick and Block Masonry: Trends, Innovations and Challenges - Proceedings of the 16th International Brick and Block Masonry Conference, IBMAC 2016",
publisher = "CRC Press/Balkema",
pages = "1531--1538",
editor = "C. Modena and \{da Porto\}, F. and M.R. Valluzzi",
booktitle = "Brick and Block Masonry",
}