Skip to main navigation Skip to search Skip to main content

The analysis of the possibilities ofthe efficiency improvement ofthe supercritical power plant integrated with CCS installation

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

2 Citations (Scopus)

Abstract

The method of integration of a supercritical coal-fired power unit with CCS installation was presented in the paper. The proposed installation is equipped with membrane modules, CO2 compressors and vacuum pumps. It allows for separation and compression of 90% of CO2 emitted from a coal-fired boiler. The way of minimization of the energy need of the mentioned installation was developed. It was brought to the optimization of the pressure ratio selection in the compressors and vacuum pumps used, to the use of gas cooler at the inlet to the mentioned machines and to the use of waste heat in the steam cycle. It permits to significantly decrease the energy need for the CCS installation. In details two possible systems of the integration of recycled heat from separated and compressed carbon dioxide with steam cycle were shown. It causes an increase the efficiency of power generation. Also, the cost of electricity production was calculated for a supercritical power plant with CCS installation.

Original languageEnglish
Title of host publicationPower Plants and Industrial Processes
PublisherAabo Akademi University
Pages99-106
Number of pages8
ISBN (Print)9781456303181
Publication statusPublished - 2010
Event23rd International Conference on Efficiency, Cost, Optimization, Simulation, and Environmental Impact of Energy Systems, ECOS 2010 - Lausanne, Switzerland
Duration: 14 Jun 2010 → 17 Jun 2010

Publication series

NameProceedings of the 23rd International Conference on Efficiency, Cost, Optimization, Simulation, and Environmental Impact of Energy Systems, ECOS 2010
Volume4

Conference

Conference23rd International Conference on Efficiency, Cost, Optimization, Simulation, and Environmental Impact of Energy Systems, ECOS 2010
Country/TerritorySwitzerland
CityLausanne
Period14/06/10 → 17/06/10

Keywords

  • CCS
  • Membrane separation
  • Supercritical power plant

ASJC Scopus subject areas

  • General Energy
  • General Environmental Science

Fingerprint