Abstract
The article presents the results of numerical calculations of external walls insulated with polystyrene with an additional fire barrier in the form of mineral wool. Two types of construction layer were established, made of monolithic reinforced concrete and autoclaved aerated concrete blocks. As a result of the calculations, temperature distributions in the cross-section of the wall were obtained, with their characteristic values in specific places. For the assumptions made, a slight temperature variation on the inner surface of the wall and high values of the temperature factor fRsi were demonstrated.
| Translated title of the contribution | Thermal insulation system with a fire barrier – numerical simulations of the distribution within the wall |
|---|---|
| Original language | Polish |
| Pages (from-to) | 46-48 |
| Number of pages | 3 |
| Journal | Materialy Budowlane |
| Volume | 585 |
| Issue number | 5 |
| DOIs | |
| Publication status | Published - 2021 |
ASJC Scopus subject areas
- Chemical Engineering (miscellaneous)
Fingerprint
Dive into the research topics of 'Thermal insulation system with a fire barrier – numerical simulations of the distribution within the wall'. Together they form a unique fingerprint.Cite this