Abstract
In the paper, results of surface tension measurements with regard to liquid copper-silver alloys with the maximum silver content of 40 % mass Ag are presented. The measurements were performed at 1373-1573 K with the use of the sessile drop method. In the study, a high-temperature microscope, coupled with a camera and a computer equipped with the software designed for experiment recording and picture analysing, was applied. In order to determine surface tension values, the least square estimation of the parameters of the system of differential equations, describing the shape of a liquid sessile drop, was used.
| Original language | English |
|---|---|
| Pages (from-to) | 193-195 |
| Number of pages | 3 |
| Journal | Archives of Metallurgy and Materials |
| Volume | 58 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - 2013 |
Keywords
- High-temperature microscope
- Liquid Cu-Ag alloys
- Sessile drop method
- Surface tension
ASJC Scopus subject areas
- Metals and Alloys
Fingerprint
Dive into the research topics of 'Surface tension of Cu-Ag alloys'. Together they form a unique fingerprint.Cite this