Signal Processing from the Radiation Detector of the Radiometric Density Meter Using the Low-Pass Infinite Impulse Response Filter in the Measurement Path in the Coal Enrichment Process Control System

  • Silesian University of Technology

Research output: Contribution to journal › Article › peer-review

1 Citation (Scopus)

Abstract

One of the most common coal preparations is enrichment in a jig using a float regulation system. The latest solutions propose to compensate for significant measurement errors of the float by introducing a radiometric density meter operating on the principle of gamma radiation absorption into the bottom product discharge zone of the jig. The signal from the radiometric density meter detector is in the form of a sequence of pulses with a Poisson time distribution, which are counted by a counter, as a form of digital low-pass filter. The requirement to maintain accuracy at an appropriate level forces the measurement time to be extended, which worsens the dynamic properties. Changes in the density of the coal–water medium have an unsteady, cyclical course, resulting from the principle of operation of the jig. The research goal was to develop an algorithm for processing the signal from the radiation detector using an IIR filter in the measurement path in a way that ensures optimization of the dynamic properties of the radiometric density meter operating in the control system of the coal enrichment process in the jig. For this purpose, a low-pass IIR filter was introduced into the measurement path to process the signal from the pulse counter. The identified course of the medium density for one cycle (the first) served as a reference signal. A first-order IIR filter was proposed, with a constant parameter selected on the basis of the reference signal and a parameter depending on the time derivative of the identified density of the medium. The mean squared error MSE was adopted as an indicator for assessing the dynamic properties of the radiometric density meter. The results of simulation tests showed that introducing an IIR filter into the measurement path gives better results in terms of the adopted criterion than using a counter with a constant measurement time. The best results (MSE = 2.05 × 10−4) were obtained using an IIR filter with a parameter that is a linear function of the derivative of the medium density over time, determined for one air pulsation cycle and applied in four subsequent cycles. These results were obtained for an adaptive first-order filter with a variable parameter a from the designated range from 0.833 to 0.999, for a measurement time of 2 ms.

Original languageEnglish
Article number227
JournalElectronics (Switzerland)
Volume13
Issue number1
DOIs
Publication statusPublished - Jan 2024

Keywords

  • adaptive digital filter
  • coal preparation
  • jigging
  • radiometric meter
  • separation density