Skip to main navigation Skip to search Skip to main content

Reliability and Repeatability of a Postural Control Test for Preterm Infants

  • Katarzyna Kniaziew-Gomoluch
  • , Andrzej Szopa
  • , Tomasz Łosień
  • , Jan Siwiec
  • , Zenon Kidoń
  • , Małgorzata Domagalska-Szopa
  • Medical University of Silesia in Katowice
  • Rehabilitation and Medical Center
  • John Paul II Pediatric Center in Sosnowiec

Research output: Contribution to journal › Article › peer-review

3 Citations (Scopus)

Abstract

Background: the current study aims to evaluate the reliability and repeatability of a new PT based on Center of Pressure (CoP) movement analysis in a repeated measures design. Methods: the examination consisted of two parts: (1) the videotaping of General Movements (GMs) and GMs assessment (GMA) and (2) Posturometric Tests (PT) in supine and prone positions. PTs were performed twice (by two investigators) in the supine and prone positions using a force plate. Based on the GMA results, infants were stratified into two groups: (1) infants with normal FMs (indicating normal future motor outcomes) (n = 18) and (2) infants with abnormal FMs (indicating later neurological dysfunction) (n = 19). Results: the comparative analysis between the groups of infants with normal FMs and abnormal FMs in PT in supine showed significant differences for all parameters that described spontaneous CoP displacement. The reliability analysis determined that all ICCs of the outcomes presented at least a moderate level of reliability. The ICCs were higher for outcomes of PT performed in the supine position than in the prone position. The ICCs were higher for outcomes of PT performed in infants with abnormal vs. normal FMs. Conclusions: although the current study yielded promising results, further longitudinal research in preterm infants should identify whether altered postural control parameters prognose future motor outcomes.

Original languageEnglish
Article number1868
JournalInternational Journal of Environmental Research and Public Health
Volume20
Issue number3
DOIs
Publication statusPublished - Feb 2023

Keywords

  • General Movements Assessment
  • center of preassure displacement
  • postural control
  • pre-term infants

ASJC Scopus subject areas

  • Pollution
  • Public Health, Environmental and Occupational Health
  • Health, Toxicology and Mutagenesis

Fingerprint

Dive into the research topics of 'Reliability and Repeatability of a Postural Control Test for Preterm Infants'. Together they form a unique fingerprint.

Cite this