Abstract
In this study, flat sheet submerged MBR (FS-SMBR) was investigated under 6 and 4 h hydraulic retention times (HRT) and 40 days solid retention time with real municipal wastewater. The implementation of the treatment system was evaluated in terms of physico-chemical and microbial analysis as well as sludge characterization. The permeate of FS-SMBR complied with the standards for reuse and non-detectable levels of faecal coliform was achieved at 6 and 4 h HRTs, with pore-blocking resistances (Rt) of 28 × 1011 and 40 × 1011/m, respectively. Examining another dominant factor, that is, sludge viscosity, the best results were acquired using HRT 4 h for domestic wastewater. Furthermore, the results obtained were validated and calibrated using the GPS-X software simulator, and the results of modelled data were completely matched with the experimental data under the same conditions.
| Original language | English |
|---|---|
| Pages (from-to) | 480-492 |
| Number of pages | 13 |
| Journal | Water and Environment Journal |
| Volume | 37 |
| Issue number | 3 |
| DOIs | |
| Publication status | Published - Aug 2023 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 6 Clean Water and Sanitation
-
SDG 11 Sustainable Cities and Communities
Keywords
- GPS-X simulator
- MBR
- flat sheet
- flux
- municipal wastewater
- treatment
ASJC Scopus subject areas
- Environmental Engineering
- Water Science and Technology
- Pollution
- Management, Monitoring, Policy and Law
Fingerprint
Dive into the research topics of 'Performance evaluation of submerged membrane bioreactor for municipal wastewater treatment: Experimental study and model validation with GPS-X software simulator'. Together they form a unique fingerprint.Cite this