Abstract

There are approx. 5.5 million residential buildings in Poland including 5 million single-family houses, 90% of which were built before 2002. Most of the existing single-family houses are not energy-efficient and a large amount of energy is wasted. It is therefore essential to develop, experimentally validate and then disseminate strategies for thermal modernization of the existing single-family houses, including strategies for ventilation systems renovation. In two-storey single-family houses with sloping roofs it is possible to locate a ventilation heat recovery (VHR) unit and ventilation ducts in the unheated roof space. The paper presents the results of tests of combined ventilation systems: mechanical ventilation with heat recovery in rooms on the second floor and stack ventilation in the rooms on the first floor. On-site measurement of the efficiency of ventilation heat recovery was performed, the airtightness of the house was measured twice before and after its improvement. The results of the experimental tests of the hybrid system were used to estimate the ventilation airflow in the house and the energy demand for ventilation. The ventilation airflow was calculated using the software CONTAM. The estimated heat demand for the tested ventilation system was 37.4 kWh/m2/season; though it seems possible to reduce it below 20 kWh/m2/season.

Original languageEnglish
Pages (from-to)123-132
Number of pages10
JournalEnergy and Buildings
Volume149
DOIs
Publication statusPublished - 15 Aug 2017

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Airflow simulation
  • Airtightness
  • Building renovation
  • Energy demand
  • Hybrid ventilation
  • On-site diagnosis

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'On-site diagnosis of hybrid ventilation system in a renovated single-family house'. Together they form a unique fingerprint.

Cite this