Abstract

Power boilers should be characterized by high flexibility in terms of loads, which results from the demand for electricity. In addition to the flexibility of the boiler, it is also important for the boiler to operate under technical minimum conditions while maintaining harmful emissions standards. A boiler operating with a technical minimum should also exhibit a stable combustion process. The paper presents the results of numerical combustion research for the minimum load of the two-pass ultra-supercritical boiler with front wall swirl burners system. The combustion stability for the minimum boiler load of 40% for the three mill system configurations has been demonstrated. Based on the numerical tests carried out in terms of obtaining the most favourable combustion conditions and the emission of harmful substances, the most favourable of them cases was indicated.

Original languageEnglish
Pages (from-to)93-114
Number of pages22
JournalArchives of Thermodynamics
Volume41
Issue number4
DOIs
Publication statusPublished - 2020

Keywords

  • Coal combustion
  • Minimum boiler load
  • Numerical simulations