Skip to main navigation Skip to search Skip to main content

Nitrification monitoring in activated sludge by oxygen uptake rate (OUR) measurements

  • Ghent University

Research output: Contribution to journal › Article › peer-review

224 Citations (Scopus)

Abstract

A simple measuring system was developed that yields information about the presence of NH4+ and NO2- nitrogen in mixed liquor samples. In addition, it allows monitoring of the rate of both NH4+ and NO2- oxidation simultaneously with the carbon substrate oxidation using OUR measurements. The method is based on the subsequent addition of NaClO3 and allylthiourea, selective inhibitors of Nitrobacter and Nitrosomonas respectively, to the mixed liquor sample in a closed batch respirometer. The presented method is valuable for detailed monitoring of the nitrification process in a reactor: it is simple, inexpensive, robust and generally applicable for nitrifying reactor systems. The measurement of NH4+ and NO2- oxidation rates enables the operator to detect the presence of NH4+ and NO2- species. This allows action to be taken to improve the performance of the system. The method is validated on a SBR. It is indicated that optimal SBR phase scheduling can be based on such OUR measurements.

Original languageEnglish
Pages (from-to)1228-1236
Number of pages9
JournalWater Research
Volume30
Issue number5
DOIs
Publication statusPublished - May 1996

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 6 - Clean Water and Sanitation
    SDG 6 Clean Water and Sanitation

Keywords

  • Activity measurements
  • Allylthiourea
  • Biological nutrient removal
  • Control
  • Inhibition
  • Nitrification
  • Oxygen uptake rate
  • Sequencing batch reactor
  • Sodium chlorate

ASJC Scopus subject areas

  • Environmental Engineering
  • Civil and Structural Engineering
  • Ecological Modeling
  • Water Science and Technology
  • Waste Management and Disposal