TY - GEN
T1 - Model matching level control for a coupled tanks system using time-scale separation technique
AU - Yurkevich, Valery D.
AU - Blachuta, Marian
AU - Grygiel, Rafal
AU - Bieda, Robert
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2017/9/19
Y1 - 2017/9/19
N2 - The problem of a level control system design for a specific connection of two tanks is discussed. We compare two algorithms for the first tank: a nonlinear feedback linearization algorthm and one based on a time-scale separation. The second technique leads to a PI controller for the level control in the first tank and either a single loop PID or a cascade of P/PI controllers for the level control in the second tank. A design methodology based on the time-scale separation technique is proposed in which controller parameters are selected such that fast and slow modes are induced in the closed-loop system. Hence, the singular perturbations method is used to analyze the closed-loop system properties. A particular feature of the considered two tanks connection is that its high frequency gain tends to infinity when the system attains equilibrium. Therefore, the fast-motion transients are analyzed based on Popov absolute stability criterion in presence of a sector-like condition in control. Numerical simulations confirm robustness with regard to plant parameters and external disturbances.
AB - The problem of a level control system design for a specific connection of two tanks is discussed. We compare two algorithms for the first tank: a nonlinear feedback linearization algorthm and one based on a time-scale separation. The second technique leads to a PI controller for the level control in the first tank and either a single loop PID or a cascade of P/PI controllers for the level control in the second tank. A design methodology based on the time-scale separation technique is proposed in which controller parameters are selected such that fast and slow modes are induced in the closed-loop system. Hence, the singular perturbations method is used to analyze the closed-loop system properties. A particular feature of the considered two tanks connection is that its high frequency gain tends to infinity when the system attains equilibrium. Therefore, the fast-motion transients are analyzed based on Popov absolute stability criterion in presence of a sector-like condition in control. Numerical simulations confirm robustness with regard to plant parameters and external disturbances.
UR - https://www.scopus.com/pages/publications/85035356829
U2 - 10.1109/MMAR.2017.8046885
DO - 10.1109/MMAR.2017.8046885
M3 - Conference contribution
AN - SCOPUS:85035356829
T3 - 2017 22nd International Conference on Methods and Models in Automation and Robotics, MMAR 2017
SP - 537
EP - 542
BT - 2017 22nd International Conference on Methods and Models in Automation and Robotics, MMAR 2017
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 22nd International Conference on Methods and Models in Automation and Robotics, MMAR 2017
Y2 - 28 August 2017 through 31 August 2017
ER -