Abstract
Changing the dynamic motion parameters of pneumatic equipment requires control of pressure and the volumetric flow rate. The article presents a study of the impact of setting control parameters and external disturbances on the positioning accuracy of pneumatic rodless double acting actuator. Testing process was carried out at different values of the parameters (adjusted to the actuator) and external loads. The probe mass was selected within guidelines (a cushioning diagram) so that the operating point was placed on the curve of limiting movement speed of the actuator..
| Original language | English |
|---|---|
| Article number | 012055 |
| Journal | IOP Conference Series: Materials Science and Engineering |
| Volume | 95 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - 3 Nov 2015 |
| Event | 3rd Modern Technologies in Industrial Engineering, ModTech 2015 - Mamaia, Romania Duration: 17 Jun 2015 → 20 Jun 2015 |
ASJC Scopus subject areas
- General Materials Science
- General Engineering
Fingerprint
Dive into the research topics of 'Influence of throttling of pneumatic actuators at the positioning accuracy'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver