Abstract
The article presents results of preliminary experimental tests regarding pressure pulsation of the gear pump with external gear design, series PGP511 manufactured by Parker Hannifin. A cycle of measurements was carried out in relation to the selected parameters of system's operation, such as: rotational speed of the pump shaft, pumping pressure and capacitance change (i.e. hydraulic capacity) of the pressure line. The obtained curves have been analyzed in terms of time and frequency.
| Original language | English |
|---|---|
| Pages (from-to) | 49-54 |
| Number of pages | 6 |
| Journal | Diagnostyka |
| Volume | 16 |
| Issue number | 2 |
| Publication status | Published - 2015 |
Keywords
- Gear pumps
- Hydrostatic drive
- Pressure pulsation
ASJC Scopus subject areas
- Software
- Mechanical Engineering
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'Influence of setting the selected parameters of hydraulic systems on pressure pulsation of gear pumps'. Together they form a unique fingerprint.Cite this