Abstract

In many medical applications it is important to detect the QRS complex in the electrocardiogram (ECG) waveform with possibly low time delay. Traditional software detectors of the QRS complex implement algorithms usually based on cascades of digital filters introduce delays up to parts of a second. Hardware QRS detectors fulfill the low delay requirements, but have worse adaptive features for the changing ECG shape. In this paper a new approach to QRS detection is presented. The proposed detector is based on a Field Programmable Analog Array (FPAA). The most interesting feature of the FPAA is the dynamic reconfigurability. This solution makes it possible to modify the parameters of particular blocks of the detector or even the whole structure during runtime, without any changes in hardware and disturbance of the system functionality. The prototype QRS detector was built using AN221E04 circuit from the Anadigm company. The reconfiguration data are calculated by the AD7020 microcontroller and downloaded to the FPAA after each QRS detection.

Original languageEnglish
Title of host publication10th IFAC Workshop on Programmable Devices and Embedded Systems, PDeS 2010 - Proceedings
PublisherIFAC Secretariat
Pages48-53
Number of pages6
EditionPART 1
ISBN (Print)9783902661951
DOIs
Publication statusPublished - 2010
Event10th IFAC Workshop on Programmable Devices and Embedded Systems, PDeS 2010 - Gliwice, Poland
Duration: 6 Oct 20107 Oct 2010

Publication series

NameIFAC Proceedings Volumes (IFAC-PapersOnline)
NumberPART 1
Volume10
ISSN (Print)1474-6670

Conference

Conference10th IFAC Workshop on Programmable Devices and Embedded Systems, PDeS 2010
Country/TerritoryPoland
CityGliwice
Period6/10/107/10/10

Keywords

  • Artificial stimulator
  • Baseline drift
  • Cardiac assist device
  • Field programmable analog array
  • Pacemaker
  • QRS detector

ASJC Scopus subject areas

  • Control and Systems Engineering

Fingerprint

Dive into the research topics of 'Hybrid qrs detection circuit based on dynamic reconfigurable field programmable analog array'. Together they form a unique fingerprint.

Cite this