Abstract
This paper presents a proposal for a historic building thermal diagnostics algorithm for the example of a historical townhouse located in Lviv, Ukraine. The authors proposed a testing and diagnostics procedure that should precede design and renovation work associated with improving the energy standard of the buildings under discussion. The procedure was presented using a case study of a selected historical building. The scope of the study included an assessment of the building's technical condition, thermal vision diagnostics, wall moisture, and water absorption in the context of protection against rain. Sample thermal and hygrothermal calculations were performed for a sample architecture element. The calculations included simulations of partition envelope behaviour after planned thermal retrofitting had been carried out. Performing the presented thermal diagnostics methods in three interlinked blocks (A, B, and C) shall ensure the proper thermal retrofitting of historical buildings in the context of their further occupancy.
| Original language | English |
|---|---|
| Article number | 5374 |
| Journal | Energies |
| Volume | 13 |
| Issue number | 20 |
| DOIs | |
| Publication status | Published - 15 Oct 2020 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 11 Sustainable Cities and Communities
Keywords
- Building diagnostics
- Historical buildings
- Internal thermal insulation
- Thermal bridges
ASJC Scopus subject areas
- Renewable Energy, Sustainability and the Environment
- Energy Engineering and Power Technology
- Energy (miscellaneous)
- Control and Optimization
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'Historic building thermal diagnostics algorithm presented for the example of a townhouse in Lviv'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver