In the present work, deposition of poly(sebacic anhydride) PSBA loaded by amoxicillin, cefazolin, or vancomycin on a previously anodized Ti-15Mo surface is presented. PSBA loaded by the drug was deposited so as not to lose the functionality of the porous oxide layer microstructure. The morphology was evaluated using scanning electron microscopy, surface roughness, and wettability. The drug concentration was evaluated using high-performance liquid chromatography. It was determined that the drugs were loaded into coatings in the range of 35.2–122.87 μg/cm2 of Ti sample. The drugs released more than 16% after 0.5 hr of the hybrid coating immersion in artificial saliva. After 3 days, the PSBA coatings were degraded by 51.3 mol %, and after 7 days by 77.8 mol %, which makes it possible to load the material by different, biologically active substances. An antimicrobial investigation of Staphylococcus aureus (DSM 24167) and Staphylococcus epidermidis (ATCC 700296) confirmed the activity of the hybrid layers against the pathogens. Hybrid layer with vancomycin best inhibits the adhesion of the bacteria, whereas coatings with amoxicillin and cefazolin showed a much better bactericidal activity. In this article, the difference in the obtained results is discussed, as well as the possibility of the application of this functional material in biomedicine.

Original languageEnglish
Pages (from-to)1568-1579
Number of pages12
JournalJournal of Biomedical Materials Research - Part B Applied Biomaterials
Volume108
Issue number4
DOIs
Publication statusPublished - 1 May 2020

Keywords

  • PSBA
  • bacteria
  • hybrid coating
  • surface treatment
  • titanium alloy

ASJC Scopus subject areas

  • Biomaterials
  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Functionalization of PEO layer formed on Ti-15Mo for biomedical application'. Together they form a unique fingerprint.

Cite this