Abstract
In this investigation, ignition processes of the methane and the propane using a high-temperature oxidizer (T oxi > T ai) with a varying oxygen concentration z O2 - the HTAC (High Temperature Air Combustion) conditions, applying a constant-volume bomb (CVB) was investigated. The influence of the initial temperature of the oxidizer T oxi was analyzed and discussed. It is shown that in order to achieve an effective reaction of ignition the oxidizer temperature needn't be maximized. Detailed evolution of ignition delay time with equivalence ratio τ ig was presented. It can be concluded that increment of oxygen concentration z O2 in oxidizer results in decrease of τ ig. Trials with propane are characterizing lower values of ignition delay time τ ig in comparison with methane.
| Original language | English |
|---|---|
| Pages (from-to) | 145-149 |
| Number of pages | 5 |
| Journal | High Temperature Materials and Processes |
| Volume | 30 |
| Issue number | 1-2 |
| DOIs | |
| Publication status | Published - Apr 2011 |
Keywords
- HTAC
- Ignition delay time
- Methane
- Propane
ASJC Scopus subject areas
- General Materials Science
- Condensed Matter Physics
- Mechanics of Materials
- Physical and Theoretical Chemistry
Fingerprint