Skip to main navigation Skip to search Skip to main content

Electrochemical and microgravimetric investigations of lead, cadmium and copper deposition and stripping on solid electrodes

  • Silesian University of Technology

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

Electroanalytical methods and quartz crystal microbalance were used to study the mechanisms of deposition and stripping of lead in the presence of cadmium or copper at solid electrodes. Interaction between atoms of different metals deposited on the electrode surface change the heights and potentials of the stripping peaks and cause major errors in metal determination. The formation of a solid solution during simultaneous electroreduction of Pb and Cu was confirmed. ASV determination of lead in the presence of cadmium also gives uncertain results because cadmium atoms are covered (blocked) by lead and can be oxidized together with lead at more positive potential.

Original languageEnglish
Pages (from-to)392-397
Number of pages6
JournalElectroanalysis
Volume15
Issue number5-6
DOIs
Publication statusPublished - Apr 2003

Keywords

  • Anodic stripping voltammetry
  • Cadmium
  • Copper
  • Lead

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry

Fingerprint

Dive into the research topics of 'Electrochemical and microgravimetric investigations of lead, cadmium and copper deposition and stripping on solid electrodes'. Together they form a unique fingerprint.

Cite this