Efficiency analysis of a hard-coal-fired supercritical power plant with a four-end high-temperature membrane for air separation

  • Silesian University of Technology

Research output: Contribution to journalArticlepeer-review

47 Citations (Scopus)

Abstract

The supercritical power plant analyzed in this paper consists of the following elements: a steam turbine, a hard-coal-fired oxy-type pulverized fuel boiler, an air separation unit with a four-end-type high-temperature membrane and a carbon dioxide capture unit. The electrical power of the steam turbine is 600MW, the live steam thermodynamic parameters are 650°C/30MPa, and the reheated steam parameters are 670°C/6MPa. First of all the net efficiency was calculated as functions of the oxygen recovery rate. The net efficiency was lower than the reference efficiency by 9-10.5. pp, and a series of actions were thus proposed to reduce the loss of net efficiency. A change in the boiler structure produced an increase in the boiler efficiency of 2.5-2.74. pp. The range of the optimal air compressor pressure ratio (19-23) due to the net efficiency was also determined. The integration of all installations with the steam turbine produced an increase in the gross electric power by up to 50.5MW. This operation enabled the replacement of the steam regenerative heat exchangers with gas-water heat exchangers. As a result of these alterations, the net efficiency of the analyzed power plant was improved to 5.5. pp less than the reference efficiency.

Original languageEnglish
Pages (from-to)109-119
Number of pages11
JournalEnergy
Volume64
DOIs
Publication statusPublished - 1 Jan 2014

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 13 - Climate Action
    SDG 13 Climate Action

Keywords

  • Air separation unit
  • High-temperature membranes
  • Oxy-combustion
  • Supercritical power plant

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Pollution
  • Mechanical Engineering
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Efficiency analysis of a hard-coal-fired supercritical power plant with a four-end high-temperature membrane for air separation'. Together they form a unique fingerprint.

Cite this