Skip to main navigation Skip to search Skip to main content

Ecologic effect of the connection of the coal fueled steam unit with the gas turbine installation

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

Abstract

The paper shows the results of calculations for a concept assuming the connection of the supercritical coal-fired power plant (SCPP, so-called reference unit) with the gas turbine installation and heat recovery system. The components of this system were: a supercritical heat recovery steam generator and two flue-gases heat exchangers used for preheating of condensate and of feed water. The presence of exchangers permits to replace regeneration and to obtain, in consequence, higher nominal power rating of steam turbine. For the reference unit and assumed structure of a multi-fuel hybrid cycle (MFHC) the key indicators of the thermodynamic and ecologic evaluation were defined. The researches were carried out for a defined gas turbine model, i.e. GE MS9171. In the course of investigation the levels of two defined in the paper ratios of regeneration replacement were changed. The values of thermodynamic and ecologic effectiveness obtained for two specified values of regeneration replacement ratios were compared with values of effectiveness indicators obtained for reference unit and three alternative technologies. This technologies were: supercritical coal-fired power plant integrated with CCS installation (SCPP+CCS), simple cycle gas turbine (SCGT) and combined cycle gas turbine (CCGT).

Original languageEnglish
Title of host publicationPower Plants and Industrial Processes
PublisherAabo Akademi University
Pages1-7
Number of pages7
ISBN (Print)9781456303181
Publication statusPublished - 2010
Event23rd International Conference on Efficiency, Cost, Optimization, Simulation, and Environmental Impact of Energy Systems, ECOS 2010 - Lausanne, Switzerland
Duration: 14 Jun 2010 → 17 Jun 2010

Publication series

NameProceedings of the 23rd International Conference on Efficiency, Cost, Optimization, Simulation, and Environmental Impact of Energy Systems, ECOS 2010
Volume4

Conference

Conference23rd International Conference on Efficiency, Cost, Optimization, Simulation, and Environmental Impact of Energy Systems, ECOS 2010
Country/TerritorySwitzerland
CityLausanne
Period14/06/10 → 17/06/10

Keywords

  • Ecologic analysis
  • Gas turbine
  • Repowering
  • Supercritical coal-fired power plant

ASJC Scopus subject areas

  • General Energy
  • General Environmental Science

Fingerprint

Dive into the research topics of 'Ecologic effect of the connection of the coal fueled steam unit with the gas turbine installation'. Together they form a unique fingerprint.

Cite this