Skip to main navigation Skip to search Skip to main content

Dynamic properties of fast gas concentration meter with nondispersive infrared detector

Research output: Contribution to journal › Article › peer-review

16 Citations (Scopus)

Abstract

Dynamic properties of fast gas concentration meters were analyzed. The impact of the sampling flow rate, the sampling tube length and the sensor chamber volume on the dynamic properties of the measurement system was tested. The correlation between the sampling flow rate, the sampling tube length and the time constant was confirmed. The dynamic properties of the meter were determined using step up and step down tests. A dynamic correction method was proposed. The aim of this method was to restore the waveform of the gas concentration changes at the sampling input of the meter on the basis of the recorded measurement results, having taken into account the pre-defined dynamic properties of the meter. The correction method was based on the Fourier transformation and was tested during the sinusoidal test.

Original languageEnglish
Pages (from-to)149-155
Number of pages7
JournalMeasurement: Journal of the International Measurement Confederation
Volume95
DOIs
Publication statusPublished - 1 Jan 2017

Keywords

  • Dynamic correction
  • Dynamic properties
  • Fast CO meter
  • Fast NDIR

ASJC Scopus subject areas

  • Instrumentation
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Dynamic properties of fast gas concentration meter with nondispersive infrared detector'. Together they form a unique fingerprint.