Skip to main navigation Skip to search Skip to main content

Concentration distribution along the electrodialyzer

Research output: Contribution to journalArticlepeer-review

19 Citations (Scopus)

Abstract

Electrodialyzer equipped with a segmented electrode was used for a desalination of a model sodium chloride solution in the diluate linear flow velocity range of 2.11-3.37cm/s, concentrate linear flow velocity range of 0.38-0.70cm/s and current density of up to 722A/m2. The observed current density distribution, concentration and velocity changes allowed for the establishment of the concentration and linear flow velocity distributions along the concentrate and diluate compartments, taking into account the solute diffusion and electromigration, the solvent osmotic and electroosmotic flux and the solvent-solute interactions. The influence of concentration distribution and concentration polarization on the gypsum scaling risk was discussed.

Original languageEnglish
Pages (from-to)94-100
Number of pages7
JournalDesalination
Volume341
Issue number1
DOIs
Publication statusPublished - 15 May 2014

Keywords

  • Concentration distribution
  • Concentration polarization
  • Electrodialysis
  • Mass transfer modeling
  • Scaling risk

ASJC Scopus subject areas

  • General Chemistry
  • General Chemical Engineering
  • General Materials Science
  • Water Science and Technology
  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'Concentration distribution along the electrodialyzer'. Together they form a unique fingerprint.