Skip to main navigation Skip to search Skip to main content

Computer and physical modeling of blood circulation pump support for a new field of application in palliative surgery

  • Foundation of Cardiac Surgery Development
  • Medical University of Silesia in Katowice

Research output: Contribution to journalArticlepeer-review

7 Citations (Scopus)

Abstract

Objectives: One of the most popular palliative procedures performed to increase pulmonary blood flow in children with congenital heart defects is a shunt operation (Blalock-Taussig graft or Glenn procedure), which creates the new blood channel to the pulmonary artery. The main problem with this kind of surgery is poor shunt effectiveness and the lack of possibility to regulate the flow. The aim of this work is to use advanced computer simulation methods to study the effectiveness of a new idea to introduce a small axial blood pump into a Blalock-Taussig (B-T) or Glenn shunt in order to control the blood flow and prevent any increase in the graft stenosis. Methods: Physical and computer 3-D simulation based on a finite element mesh (FEM) model was applied. Studies for optimization of the shunt and hybrid shunt with pump were performed for different stages of the disease. Results and Conclusion: The graft with the axial pump creates good conditions for the vascular system and pulmonary artery blood flow as well as regulating blood pressure under variable conditions caused by palliative procedures. Its use permits the afterload of the left heart ventricle to be decreased. A palliative procedure is only a temporary solution. When a child grows, while the graft size is fixed, the blood flow through this graft may be not sufficient under changing hemodynamic conditions. The use of an axial pump for regulating the blood flow volume, during palliative procedures, allows to obtain the optimal flow conditions in pulmonary artery and safely wait on the final cardiac surgery correction later. However, the use of a pump mounted inside the graft increased hemodynamic resistance, which caused the flow to decrease up to 70% in the graft when the axial pump was not working.

Original languageEnglish
Pages (from-to)1068-1074
Number of pages7
JournalInternational Journal of Artificial Organs
Volume30
Issue number12
DOIs
Publication statusPublished - Dec 2007

Keywords

  • Blood pump
  • Cardiac circulation
  • Computer simulation
  • Palliative procedures
  • Physical modeling

ASJC Scopus subject areas

  • Bioengineering
  • Medicine (miscellaneous)
  • Biomaterials
  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Computer and physical modeling of blood circulation pump support for a new field of application in palliative surgery'. Together they form a unique fingerprint.

Cite this