Comparative assessment of the effectiveness of a free-piston Stirling engine-based micro-cogeneration unit and a heat pump

Research output: Contribution to journalArticlepeer-review

29 Citations (Scopus)

Abstract

In this article, a comparison of the thermodynamic and economic effectiveness of two heating systems dedicated to residential applications is presented: a natural gas-fueled micro-cogeneration unit based on a free-piston Stirling engine that generates additional electric energy, and a heat pump system. The measurements of the heat pump system as well as those of the energy (electricity and heat) demand profiles in the analyzed heating season were conducted in a single-family house. The measurements of the μCHP unit were made using a laboratory stand prepared for simulating a variable heat demand. The efficiency of electric energy generation in the μCHP unit was in the range of 7.2%–12.7%, and the overall efficiency was in the range of 88.6%–92.4%. The economic evaluation of the μCHP unit revealed a slight loss compared to the operation of the heat pump throughout the heating season. Sensitivity analysis of the unit price of natural gas and electric energy was performed, and revealed that a reduction in the gas price or an increase in the purchase price of electricity at 2% would have a beneficial financial effect when operating a μCHP system as compared to a heat pump.

Original languageEnglish
Pages (from-to)134-147
Number of pages14
JournalEnergy
Volume148
DOIs
Publication statusPublished - 1 Apr 2018

Keywords

  • Cost analysis
  • Heat pump
  • Micro-cogeneration
  • Stirling engine

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Modeling and Simulation
  • Renewable Energy, Sustainability and the Environment
  • Fuel Technology
  • Energy Engineering and Power Technology
  • Pollution
  • General Energy
  • Mechanical Engineering
  • Industrial and Manufacturing Engineering
  • Management, Monitoring, Policy and Law
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Comparative assessment of the effectiveness of a free-piston Stirling engine-based micro-cogeneration unit and a heat pump'. Together they form a unique fingerprint.

Cite this