Abstract
Experiments for removal of organic compounds (expressed as COD) from "young" municipal landfill leachate, using oxidation by H 2O 2, UV photooxidation and UV/H 2O 2 process, were carried out on a laboratory scale. Studies have shown that the most effective method was UV/H 2O 2 process. When oxidation was conducted under the most suitable conditions (parameters found during experiments), maximum value of COD removal equaled 74.6%, 19.6% and 19.3% when the treatment was realized by use Of H 2O 2/UV, H 2O 2 and UV radiation, respectively. These results demonstrate that in order to attain high efficiency of COD removal, use of advanced oxidation process (H 2O 2/UV) is necessary.
| Original language | English |
|---|---|
| Pages (from-to) | 5-13 |
| Number of pages | 9 |
| Journal | Environment Protection Engineering |
| Volume | 38 |
| Issue number | 3 |
| DOIs | |
| Publication status | Published - 2012 |