TY - JOUR
T1 - CIRCA
T2 - comprehensible online system in support of chest X-rays-based screening by COVID-19 example
AU - POLCOVID Study Group
AU - Prazuch, Wojciech
AU - Suwalska, Aleksandra
AU - Socha, Marek
AU - Tobiasz, Joanna
AU - Foszner, Pawel
AU - Jaroszewicz, Jerzy
AU - Gruszczynska, Katarzyna
AU - Sliwinska, Magdalena
AU - Nowak, Mateusz
AU - Gizycka, Barbara
AU - Zapolska, Gabriela
AU - Popiela, Tadeusz
AU - Przybylski, Grzegorz
AU - Fiedor, Piotr
AU - Pawlowska, Malgorzata
AU - Flisiak, Robert
AU - Simon, Krzysztof
AU - Walecki, Jerzy
AU - Cieszanowski, Andrzej
AU - Szurowska, Edyta
AU - Plesniak, Robert
AU - Sznajder, Katarzyna
AU - Blewaska, Piotr
AU - Rajewski, Pawel
AU - Rabiko, Piotr
AU - Rataj, Katarzyna
AU - Klaude, Krzysztof
AU - Mazur, Samuel
AU - Wasilewski, Piotr
AU - Piotrowski, Damian
AU - Baron, Jan
AU - Krutul-Walenciej, Katarzyna
AU - Hildebrandt, Sebastian
AU - Kozanecka, Anna
AU - Kozub, Justyna
AU - Drabik, Grzegorz
AU - Tur, Adrianna
AU - Chmielarz, Przemyslaw
AU - Rataj, Mateusz
AU - Golebiewski, Bogumil
AU - Oronowicz-Jaskowiak, Agnieszka
AU - Marczyk, Michal
AU - Polanska, Joanna
N1 - Publisher Copyright:
© The Author(s) 2025.
PY - 2025/12
Y1 - 2025/12
N2 - Chest X-rays (CXRs) are widely used for diagnosing respiratory diseases, including the recent example of COVID-19. Supervised deep learning techniques can help detect cases faster and monitor disease progression. However, they are usually developed using coarser data annotations, which may insufficiently capture the heterogeneous disease portrait. We propose the pipeline called CIRCA (https://circa.aei.polsl.pl) for a CXR-based screening support system, developed using 6 diverse datasets. Our tool includes lung segmentation, quantitative assessment of data heterogeneity, and a hierarchical three-class decision system using a convolutional network and radiomic features. Lung segmentation showed an accuracy of ~ 94% in the validation and test sets, while classification accuracy was equal 86%, 83%, and 72% for normal, COVID-19, and other pneumonia classes in the independent test set. Three radiomically distinct subtypes were identified per class. In the hold-out set, the classification subtype-specific cross-dataset NPV ranged from 95 to 100%, with PPV from 86 to 100% for all subtypes except N3 (early stage or convalescent) and both C3 and P3 (probable co-occurrence of COVID-19). Using an independent test set gave similar results. The dataset-specific subtype proportions combined with various predictive qualities of subtypes partly explain the widely reported poor generalization of AI-based prediction systems.
AB - Chest X-rays (CXRs) are widely used for diagnosing respiratory diseases, including the recent example of COVID-19. Supervised deep learning techniques can help detect cases faster and monitor disease progression. However, they are usually developed using coarser data annotations, which may insufficiently capture the heterogeneous disease portrait. We propose the pipeline called CIRCA (https://circa.aei.polsl.pl) for a CXR-based screening support system, developed using 6 diverse datasets. Our tool includes lung segmentation, quantitative assessment of data heterogeneity, and a hierarchical three-class decision system using a convolutional network and radiomic features. Lung segmentation showed an accuracy of ~ 94% in the validation and test sets, while classification accuracy was equal 86%, 83%, and 72% for normal, COVID-19, and other pneumonia classes in the independent test set. Three radiomically distinct subtypes were identified per class. In the hold-out set, the classification subtype-specific cross-dataset NPV ranged from 95 to 100%, with PPV from 86 to 100% for all subtypes except N3 (early stage or convalescent) and both C3 and P3 (probable co-occurrence of COVID-19). Using an independent test set gave similar results. The dataset-specific subtype proportions combined with various predictive qualities of subtypes partly explain the widely reported poor generalization of AI-based prediction systems.
KW - COVID-19
KW - Chest X-ray
KW - Classification
KW - Deep learning
KW - Heterogeneous disease
KW - Lung segmentation
UR - https://www.scopus.com/pages/publications/105023334150
U2 - 10.1038/s41598-025-26895-0
DO - 10.1038/s41598-025-26895-0
M3 - Article
C2 - 41315612
AN - SCOPUS:105023334150
SN - 2045-2322
VL - 15
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 42732
ER -