Abstract
The paper presents results of investigating stability of chromic-manganic austenite of used rotor retaining rings. The magnetic measurements based on the detection of the instable austenite, which in the mechanical and thermal correlations constitute an alternative for the diagnostic testing and moreover they provide more complete picture of the retaining ring exploitation.