Assessment of gold with titanium alloy weldability in conditions of a dental technique laboratory

  • Praktyka Stomatologiczna Barbara Radecka

Research output: Contribution to journal › Article › peer-review

1 Citation (Scopus)

Abstract

Purpose: In dental practice, there is necessary to weld gold with titanium under the conditions of a dental technique laboratory, which is difficult. The aim was to assess the weldability of pure gold with the titanium alloy Ti6Al4V using a prosthetic laser welding machine. Design/methodology/approach: Gold wire in a diameter of 0.4 mm made with the use of a jewellery drawbar (GOLDPORT, Szczecin, Poland) was welded to a titanium alloy Ti6Al4V substrate of dental implant abutment screw (MegaGen). Dental laser welding parameters (Bego Laser Star T plus) were 230 V; 6.5 ms; 2.5 Hz; laser spot 0.3 mm, and argon blow. Samples were included in resin, ground (500-4000 SiC), polished (Al2O3 suspension) and etched (Kroll solution) per 20 s before observation under a light microscope. Findings: There were well-welded and poorly joined zones. The discontinuities and voids there were not visible or sparse next to the initial weld point. Dendritic structure at well-welded remelting zones and two-phase microstructure of titanium and Ti3Au phase were found. The heat-affected zone was about of 20 microns. Research limitations/implications: Light microscopy was used, and precise phase identification required further investigations. Weld strength assessment requires further micro-hardness and load-bearing ability tests. Weldability concerns the model system with pure gold. Practical implications: In the case of elements with dimensions below 0.4 mm, the use of a laser with a smaller spot should be considered for better control of the remelting zone and mechanical positioning of the elements in order to stabilize and avoid discontinuities and voids. Originality/value: Prosthetic laser welding with a laser spot about of 0.3 mm allows to obtain well-welded parts of 0.3 mm in diameter under stable stitching conditions and higher than 0.4 mm in dimensions.

Original languageEnglish
Pages (from-to)36-41
Number of pages6
JournalArchives of Materials Science and Engineering
Volume118
Issue number1
DOIs
Publication statusPublished - 1 Nov 2022

Keywords

  • Gold
  • Implant denture
  • Laser welding
  • Microstructure
  • Prosthetic dentistry
  • Titanium alloy

ASJC Scopus subject areas

  • General Materials Science

Fingerprint

Dive into the research topics of 'Assessment of gold with titanium alloy weldability in conditions of a dental technique laboratory'. Together they form a unique fingerprint.

Cite this