Abstract
The study shows the results of studies concerning the hydraulic permeability of ultrafiltration and hybrid in-line coagulation-UF (without sedimentation) systems during the treatment of water containing higher concentrations of organic matter. The calculation of UF permeability was made employing a model in a non-stationary process based on the change of the volume permeate flux over time, determining the time constant t0 and a resistance model analyzing the resistance caused by the interaction of membrane-water contaminants, determining the constant tRO. The tests were conducted using a seven-channel ceramic membrane, cut-off 15 kDa. It has been found that the models adequately characterize both direct UF and the hybrid system, and the calculated values fit the experimental results.
| Original language | English |
|---|---|
| Pages (from-to) | 100-110 |
| Number of pages | 11 |
| Journal | Desalination |
| Volume | 239 |
| Issue number | 1-3 |
| DOIs | |
| Publication status | Published - Apr 2009 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 6 Clean Water and Sanitation
Keywords
- Ceramic membranes
- In-line coagulation
- Ultrafiltration
- Water treatment
ASJC Scopus subject areas
- General Chemistry
- General Chemical Engineering
- General Materials Science
- Water Science and Technology
- Mechanical Engineering
Fingerprint
Dive into the research topics of 'Application of mathematical models to the calculation of ultrafiltration flux in water treatment'. Together they form a unique fingerprint.Cite this