Abstract
This paper presents an analysis of the thermal cycle of a supercritical 900 MWe condensing power plant which meets the "CCS ready" requirements. This means that once CO2 capture installations become commercially available, they will be added to the thermal cycle. The C0 2 separation method selected for the analysis is chemical absorption using MEA as sorbent with different energy consumption. The analysis also takes into account the operation of an eight-stage geared compressor which satisfies the needs of CO2 transport. The calculations are performed for a power unit fired with hard and brown coal. The change in the power plant operation indices after its integration with a separation installation is presented as a function of the sorbent energy consumption.
| Translated title of the contribution | An analysis of the operation of a "CCS ready" power plant integrated with CO2 capture from flue gases for different energy consumption of mea |
|---|---|
| Original language | Polish |
| Pages (from-to) | 104-109 |
| Number of pages | 6 |
| Journal | Rynek Energii |
| Volume | 110 |
| Issue number | 1 |
| Publication status | Published - 2014 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 13 Climate Action
ASJC Scopus subject areas
- General Mathematics
- General Energy
Fingerprint
Dive into the research topics of 'An analysis of the operation of a "CCS ready" power plant integrated with CO2 capture from flue gases for different energy consumption of mea'. Together they form a unique fingerprint.Cite this